These products are oil fired thermal oil boilers. The operation is simple. The Radiation and convective helical coil absorb maximum heat from the hot flue gases in radiation zone and twice in convection zone in cross-flow pattern. The residual heat in the flue gases are picked up by the incoming combustion air ensure optimum heat utilization.
Other Features are:
The 3-pass Thermal heater with integral air heater achieves a super efficiency of 88 %.
SUPRATHERM SYSTEM ADVANTAGE
A thermal fluid system can function between 100 C and 350 C without any pressure increase. The Thermal system requires mineral oil as heat transfer media, which is non- corrosive and free from any foreign particles. This ensures low maintenance cost and higher reliability.
SAFETY AND CONTROLS
Thermal system provides various safety interlocks, indicators and alarms for a safe and reliable operation.
Technical Specifications
Oil Capacity Inside | 1.48 m3 |
Material | Mild Steel |
Weight | 6550 kg |
Style | Vertical |